ZHCSKD1C October 2019 – January 2021 TCA9511A
PRODUCTION DATA
In order to ensure that the part starts up in the correct state, it is recommended that the power supply ramp rates meet the below requirements.
Parameter | MIN | MAX | UNIT | ||
---|---|---|---|---|---|
tRT | Rise rate | 0.1 | 1000 | ms | |
tFT | Fall rate | 0.1 | 1000 | ms |