ZHCSKS6B June   2020  – August 2024 AMC3330

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Recommended Operating Conditions
    4. 5.4  Thermal Information
    5. 5.5  Power Ratings
    6. 5.6  Insulation Specifications
    7. 5.7  Safety-Related Certifications 
    8. 5.8  Safety Limiting Values
    9. 5.9  Electrical Characteristics
    10. 5.10 Switching Characteristics
    11. 5.11 Timing Diagram
    12. 5.12 Insulation Characteristics Curves
    13. 5.13 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Analog Input
      2. 6.3.2 Isolation Channel Signal Transmission
      3. 6.3.3 Analog Output
      4. 6.3.4 Isolated DC/DC Converter
      5. 6.3.5 Diagnostic Output and Fail-Safe Behavior
    4. 6.4 Device Functional Modes
  8. Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Typical Application
      1. 7.2.1 Design Requirements
      2. 7.2.2 Detailed Design Procedure
        1. 7.2.2.1 Input Filter Design
        2. 7.2.2.2 Differential to Single-Ended Output Conversion
      3. 7.2.3 Application Curve
    3. 7.3 Best Design Practices
    4. 7.4 Power Supply Recommendations
    5. 7.5 Layout
      1. 7.5.1 Layout Guidelines
      2. 7.5.2 Layout Example
  9. Device and Documentation Support
    1. 8.1 Device Support
      1. 8.1.1 Device Nomenclature
    2. 8.2 Documentation Support
      1. 8.2.1 Related Documentation
    3. 8.3 接收文档更新通知
    4. 8.4 支持资源
    5. 8.5 Trademarks
    6. 8.6 静电放电警告
    7. 8.7 术语表
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

特性

  • 3.3V 或 5V 单电源运行,具有集成直流/直流转换器
  • ±1V 输入电压范围,针对使用高输入阻抗的电压测量进行了优化
  • 固定增益:2.0
  • 低直流误差:
    • 增益误差:±0.2%(最大值)
    • 增益漂移:±45ppm/°C(最大值)
    • 失调电压误差:±0.3mV(最大值)
    • 失调电压温漂:±4µV/°C(最大值)
    • 非线性度:±0.02%(最大值)
  • 高 CMTI:85kV/µs(最小值)
  • 系统级诊断功能
  • 安全相关认证:
    • 符合 DIN EN IEC 60747-17 (VDE 0884-17) 的 6000VPK 增强型隔离
    • 4250VRMS 隔离,符合 UL1577 标准且持续时长为 1 分钟
  • 符合 CISPR-11 和 CISPR-25 EMI 标准