ZHCSM06C december 2020 – may 2023 TPS272C45
PRODUCTION DATA
Parameter | Test Conditions | Min | Typ | Max | ||
---|---|---|---|---|---|---|
Unit | ||||||
tDR | CH1 and CH2 Turnon delay time | VS = 24 V, RL = 48 Ω 50% of EN to 10% of VOUT | 10 | 15 | 25 | µs |
tDF | CH1 and CH2 Turnoff delay time | VS = 24 V, RL = 48 Ω 50% of EN to 90% of VOUT | 25 | 35 | 50 | µs |
SR2R | VOUTx rising slew rate | VS = 24 V, 25% to 75% of VOUT, RL = 48 Ω |
0.45 | 0.65 | 1.05 | V/µs |
SR2F | VOUTx falling slew rate | VS = 24 V, 75% to 25% of VOUT, RL = 48 Ω |
0.5 | 0.9 | 1.4 | V/µs |
fmax | Maximum PWM frequency | 1 | kHz | |||
tON | CH1 and CH2 Turnon time | VS = 24 V, RL = 48 Ω 50% of EN to 90% of VOUT | 25 | 40 | 65 | µs |
tOFF | CH1 and CH2 Turnoff time | VS = 24 V, RL = 48 Ω 50% of EN to 10% of VOUT | 40 | 50 | 80 | µs |
tON - tOFF | CH1 and CH2 Turnon and off matching | 1ms ON time switch enable pulse VBB = 24 V, RL = 48 Ω | –25 | 0 | 25 | µs |
ΔPWM | CH1 and CH2 PWM accuracy - average load current | 200-µs enable pulse, VS = 24 V, RL = 48 Ω F = fmax |
–12.5 | 0 | 12.5 | % |
ΔPWM | CH1 and CH2 PWM accuracy - average load current | 100-µs enable pulse, VS = 24 V, RL = 48 Ω F = fmax |
–20 | 10 | % | |
tON - tOFF | CH1 Turnon and off timing matching | 100-µs enable pulse, VS = 24 V, RL = 48 Ω F = fmax |
–40 | 10 | µs | |
EON | Switching energy losses during turnon | VS = 24 V, RL = 8 Ω, 1 ms pulse, VOUT from 10% to 90% of VS voltage | 0.3 | 0.4 | mJ | |
EOFF | Switching energy losses during turnoff | VS = 24 V, RL = 8 Ω, 1 ms pulse, VOUT from 10% to 90% of VS voltage | 0.25 | 0.35 | mJ |