ZHCSMW7B december   2020  – february 2023 TPS22950

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Device Comparison Table
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Switching Characteristics
    7. 7.7 Typical Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1 Current Limiting (TPS22950, TPS22950C)
      2. 9.3.2 Current Limiting (TPS22950L)
      3. 9.3.3 Adjusting the Current Limit
      4. 9.3.4 Reverse Current Blocking (TPS22950, TPS22950C)
    4. 9.4 Device Functional Modes
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
      3. 10.2.3 Application Curves
    3. 10.3 Power Supply Recommendations
    4. 10.4 Layout
      1. 10.4.1 Layout Guidelines
      2. 10.4.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 接收文档更新通知
    2. 11.2 支持资源
    3. 11.3 Trademarks
    4. 11.4 静电放电警告
    5. 11.5 术语表
  12. 12Mechanical, Packaging, and Orderable Information

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)(1)
MIN MAX UNIT
VIN Maximum Input Voltage Range –0.3 6 V
VOUT Maximum Output Voltage Range –0.3 6 V
VON Maximum ON Pin Voltage Range –0.3 6 V
VFLT Maximum FLT Pin Voltage –0.3 6 V
IMAX Maximum Continuous Output Current(TPS22950C) 3.2 A
IMAX Maximum Continuous Output Current(TPS22950,TPS22950L) 2.7 A
IMAX,PLS Maximum Pulsed Output Current (TJ = 85°C, duty cycle = 2%) 4.1 A
TSTG Storage temperature –65 150 °C
TLEAD Maximum Lead Temperature (10 s soldering time) 300 °C
Stresses beyond those listed under Absolute Maximum Rating may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Condition. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.