ZHCUBL4A December 2023 – August 2024
图 4-8 和表 4-3 展示了在 400V 直流链路输出时,在升压模式下运行的双向直流/直流转换器的效率。所考虑的输入电池电压为 80V、160V、240V 和 320V,该表显示转换器可分别实现 97.7%、98.8%、99.3% 和 99.5% 的峰值效率。
输出功率 | 效率(VBat=80V) | 输出功率 | 效率(VBat=160V) | 输出功率 | 效率(VBat=240V) | 输出功率 | 效率(VBat=320V) |
---|---|---|---|---|---|---|---|
0.1kW | 95.6% | 0.2kW | 97.0% | 0.6kW | 98.7% | 0.8kW | 99.1% |
0.2kW | 96.4% | 0.5kW | 98.3% | 1.0kW | 99.0% | 1.3kW | 99.3% |
0.4kW | 97.0% | 0.9kW | 98.5% | 1.6kW | 99.1% | 2.1kW | 99.4% |
0.6kW | 97.1% | 1.2kW | 98.8% | 2.0kW | 99.2% | 2.7kW | 99.4% |
0.7kW | 97.3% | 1.8kW | 98.6% | 2.5kW | 99.2% | 3.4kW | 99.4% |
0.9kW | 97.6% | 2.1kW | 98.8% | 3.0kW | 99.2% | 4.0kW | 99.5% |
1.0kW | 97.6% | 2.5kW | 98.8% | 3.4kW | 99.3% | 4.5kW | 99.5% |
1.2kW | 97.6% | 2.8kW | 98.8% | 4.0kW | 99.2% | 5.3kW | 99.5% |
1.4kW | 97.7% | 3.1kW | 98.8% | 4.4kW | 99.2% | 5.9kW | 99.4% |
1.5kW | 97.6% | 3.4kW | 98.8% | 5.0kW | 99.2% | 6.6kW | 99.4% |
1.7kW | 97.6% | 3.7kW | 98.7% | 5.4kW | 99.2% | 7.2kW | 99.4% |
1.8kW | 97.4% | 4.1kW | 98.6% | 5.8kW | 99.2% | ||
2.0kW | 97.3% | 4.4kW | 98.6% | 6.4kW | 99.1% | ||
2.2kW | 97.0% | 4.5kW | 98.5% | 6.9kW | 99.0% | ||
2.4kW | 96.8% |
升压模式的结果与降压模式的结果类似,但低功耗时的损耗更高,因此效率较低。这是由于升压运行以及 GaN FET 在升压到更高电压时的更高损耗所致。
图 4-10 展示了在升压模式下转换器工作期间其中一个桥臂的开关节点的电压。从图中可以看到尖锐的开关边缘,没有过冲和振铃。可以观察到上升时间约为 30ns。
GaN 结温如图 4-11 所示。其他 GaN 具有相似的温度曲线。这种运行对应于将 VBat 240V 转换为 400V 的直流链路电压。温度不会高于 70°C。