SLVSEG2B September   2018  – September 2022 TVS3301

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Description (continued)
  6. Device Comparison Table
  7. Pin Configuration and Functions
  8. Specifications
    1. 8.1 Absolute Maximum Ratings
    2. 8.2 ESD Ratings - JEDEC
    3. 8.3 ESD Ratings - IEC
    4. 8.4 Recommended Operating Conditions
    5. 8.5 Thermal Information
    6. 8.6 Electrical Characteristics
    7. 8.7 Typical Characteristics
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
    4. 9.4 Device Functional Modes
      1. 9.4.1 Protection Specifications
      2. 9.4.2 Reliability Testing
      3. 9.4.3 Minimal Derating
      4. 9.4.4 Bidirectional Operation
      5. 9.4.5 Transient Performance
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
      3. 10.2.3 Application Curves
      4. 10.2.4 PLC Surge Protection Reference Design
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Documentation Support
      1. 13.1.1 Related Documentation
    2. 13.2 Receiving Notification of Documentation Updates
    3. 13.3 Support Resources
    4. 13.4 Trademarks
    5. 13.5 Electrostatic Discharge Caution
    6. 13.6 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Features

  • Functional Safety-Capable
  • Protection against 1-kV, 42-Ω IEC 61000-4-5
    surge test for industrial signal lines
  • Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
  • Clamping voltage of 40 V at 27-A of 8/20-µs
    surge current
  • Standoff voltage: ±33 V
  • Small 3 mm × 3 mm SON footprint
  • Survives over 5,000 repetitive strikes of 25-A
    8/20-µs surge current
  • Robust surge protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3 A
  • Low leakage current
    • 2.5-nA typical at 27°C
    • 450-nA maximum at 85°C
  • Low capacitance: 54 pF
  • Integrated level 4 IEC 61000-4-2 ESD protection