SBASAQ0
March 2023
AMC23C15-Q1
PRODUCTION DATA
1
Features
2
Applications
3
Description
4
Revision History
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Power Ratings
6.6
Insulation Specifications
6.7
Safety-Related Certifications
6.8
Safety Limiting Values
6.9
Electrical Characteristics
6.10
Switching Characteristics
6.11
Timing Diagrams
6.12
Insulation Characteristics Curves
6.13
Typical Characteristics
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
Analog Input
7.3.2
Reference Input
7.3.3
Isolation Channel Signal Transmission
7.3.4
Open-Drain Digital Outputs
7.3.5
Power-Up and Power-Down Behavior
7.3.6
VDD1 Brownout and Power-Loss Behavior
7.4
Device Functional Modes
8
Application and Implementation
8.1
Application Information
8.2
Typical Application
8.2.1
Overcurrent and Short-Circuit Current Detection
8.2.1.1
Design Requirements
8.2.1.2
Detailed Design Procedure
8.2.2
Application Curves
8.3
Best Design Practices
8.4
Power Supply Recommendations
8.5
Layout
8.5.1
Layout Guidelines
8.5.2
Layout Example
9
Device and Documentation Support
9.1
Documentation Support
9.1.1
Related Documentation
9.2
Receiving Notification of Documentation Updates
9.3
Support Resources
9.4
Trademarks
9.5
Electrostatic Discharge Caution
9.6
Glossary
10
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
DWV|8
MPDS382B
Thermal pad, mechanical data (Package|Pins)
Orderable Information
sbasaq0_oa
sbasaq0_pm
1
Features
AEC-Q100 qualified for automotive applications:
Temperature grade 1: –40°C to +125°C, T
A
Wide high-side supply range: 3 V to 27 V
Low-side supply range: 2.7 V to 5.5 V
Dual window comparator:
Window comparator 1: ±5-mV to ±300-mV adjustable threshold
Window comparator 2: ±60-mV fixed threshold
Supports positive-comparator mode:
Cmp0: 600-mV to 2.7-V adjustable threshold
Cmp2: 60-mV fixed threshold
Cmp1 and Cmp3: Disabled
Reference for threshold adjustment: 100 μA, ±1%
Trip threshold error: ±1% (max) at 250 mV
Open-drain outputs
Propagation delay: 280 ns (typ)
High CMTI: 15 V/ns (min)
Safety-related certifications:
7000-V
PK
reinforced isolation per DIN EN IEC 60747-17 (VDE 0884-17)
5000-V
RMS
isolation for 1 minute per UL1577