SNVSBY2A
January 2021 – June 2021
UCC12051-Q1
PRODUCTION DATA
1
Features
2
Applications
3
Description
4
Revision History
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Power Ratings
6.6
Insulation Specifications
6.7
Safety-Related Certifications
6.8
Safety Limiting Values
6.9
Electrical Characteristics
6.10
Switching Characteristics
6.11
Insulation Characteristics Curves
6.12
Typical Characteristics
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
Enable and Disable
7.3.2
UVLO, Power-Up, and Power-Down Behavior
7.3.3
VISO Load Recommended Operating Area
7.3.4
Thermal Shutdown
7.3.5
External Clocking and Synchronization
7.3.6
VISO Output Voltage Selection
7.3.7
Electromagnetic Compatibility (EMC) Considerations
7.4
Device Functional Modes
8
Application and Implementation
8.1
Application Information
8.2
Typical Application
8.2.1
Design Requirements
8.2.2
Detailed Design Procedure
8.2.2.1
VISO Output Capacitor Selection
8.2.3
Application Curves
9
Power Supply Recommendations
10
Layout
10.1
Layout Guidelines
10.2
Layout Example
11
Device and Documentation Support
11.1
Device Support
11.1.1
Development Support
11.2
Documentation Support
11.2.1
Related Documentation
11.3
Receiving Notification of Documentation Updates
11.4
Support Resources
11.5
Trademarks
11.6
Electrostatic Discharge Caution
11.7
Glossary
12
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
DVE|16
MPSS113C
Thermal pad, mechanical data (Package|Pins)
Orderable Information
snvsby2a_oa
snvsby2a_pm
1
Features
High-efficiency DC/DC converter with integrated transformer technology
AEC-Q100 qualified with the following results:
Device temperature Grade 1: –40°C to 125°C ambient operating Temperature
Functional Safety-Capable
Documentation available to aid functional safety system design
Output power (typical): 500 mW
Regulated 5 V or 3.3 V output with selectable 400 mV headroom voltage to power an LDO
Input voltage: 4.5 V to 5.5 V
Robust isolation barrier:
Isolation rating: 5 kV
RMS
Surge capability:
10
kV
PK
Working voltage:
1.2 k
V
RMS
Minimum CMTI: 100 V/ns
Short circuit recovery
Thermal shutdown
16-pin wide-body SOIC package with > 8-mm creepage and clearance
Safety-related certifications (planned):
7071-V
PK
reinforced isolation per DIN V VDE V 0884-11:2017-01
5000
-V
RMS
isolation for 1 minute per UL 1577
UL certification per IEC 60950-1 and IEC 62368-1 end equipment standards
CQC approval per GB4943.1-2011