This multi-functional evaluation module (EVM) is designed for the evaluation of the ISO1050 isolated CAN transceiver. Input and output connections, as well as test points for measurements, are provided to help you use this device which is the world's first CAN transceiver with integrated isolation.

Features
  • 4000-VPEAK isolation
  • Failsafe outputs
  • Low loop delay: 150 ns typical
  • 50-kV/µs typical transient immunity
  • Meets or exceeds the requirements of ISO 11898
  • Bus-fault protection of –27 V to +40 V
  • Dominant timeout function
  • UL 1577, IEC 60747-5-2 (VDE 0884, Rev.2), IEC 61010-1, IEC 60950-1 and CSA approval pending
  • 3.3-V inputs are 5-V tolerant
Isolated CAN transceivers
ISO1050 Isolated 5-V CAN transceiver
Download View video with transcript Video

Order & start development

Evaluation board

ISO1050EVM — ISO1050 isolated CAN transceiver evaluation module

Log in to order
In stock / Out of stock
Limit:
Not available on TI.com
TI's Standard Terms and Conditions for Evaluation Items apply.

Technical documentation

No results found. Please clear your search and try again.
View all 3
Type Title Date
Data sheet ISO1050 Isolated CAN Transceiver datasheet (Rev. L) PDF | HTML 03 Oct 2023
Certificate ISO1050EVM EU Declaration of Conformity (DoC) 02 Jan 2019
EVM User's guide Isolated CAN EVM User's Guide 02 Jul 2009