TIDA-010037
スタンドアロン ADC を使用した高精度、相分割 CT(電流トランス)電気メーターのリファレンス・デザイン
TIDA-010037
概要
This reference design implements Class 0.1 split-phase energy measurement using high-performance, multi-channel analog-to-digital converters (ADC). The independent ADC samples the output of current transformers (CT) at 8 kHz to measure the current and voltage of each leg of the AC mains. The reference design can achieve high accuracy across a wide input current range (0.05–100 amps) and supports high sampling frequencies necessary for advanced power quality features such as individual harmonic analysis. Using an independent ADC to sample the CT output provides designers greater flexibility in the choice of metrology microcontrollers when compared to integrated SoCs and dedicated application-specific products. The reference design uses a SimpleLink™ ARM Cortex-M4 host microcontroller to calculate energy measurement parameters.
特長
- Split-phase metrology for electricity meters that meets ANSI C12.20 Class 0.1 active energy accuracy requirements across 10000:1 input range
- Active and reactive energy and power, root mean square (RMS) current and voltage, power factor, and line-frequency calculations
- Isolated RS-232 and RS-485 with 5 kV RMS isolation
- Communications module expansion with current limit and overvoltage and undervoltage protection
- Tested across 50 mA to 100A input range
- Complete, tested reference design with hardware files and design guide
組み立てられたボードは、テストと性能検証のみの目的で開発されたものであり、販売していません。
設計ファイルと製品
設計ファイル
すぐに使用できるシステム・ファイルをダウンロードすると、設計プロセスを迅速化できます。
設計に使用したコンポーネント、参照指定子、メーカー名や型番などを記入した詳細なリスト
製品
設計や代替製品候補に TI 製品を含めます。
技術資料
種類 | タイトル | 英語版のダウンロード | 日付 | |||
---|---|---|---|---|---|---|
* | 設計ガイド | スタンドアロンを使用した高精度の分相 CT 電気メーターのリファレンス・デザイン (Rev. B) | PDF | HTML | 2020年 10月 9日 |