This reference design implements a single-phase with neutral or split-phase energy measurement subsystem using one isolated and one non-isolated standalone multichannel analog-to-digital converters (ADCs) with two shunts. The combination of shunt sensors and a low-power linear 3D Hall-effect sensor, TMAG5273, provides both protection and enables the detection of magnetic tampering attacks. The reference design achieves class 0.2 S accuracy across 4000:1 input range (25mA to 100A) with 4kHz sampling rate and uses a TI Arm® Cortex®-M0+ host microcontroller for calculating the metrology parameters. The necessary software functionality is implemented in MSPM0-SDK Version: 2.01.00.03 and can be compiled with TI Code Composer Studio™.
特長
- Single-phase two-wire (1P2W) class 0.2 S shunt metrology subsystem for electricity meters
- Split-phase two-wire (2P2W) class 0.2 S shunt metrology subsystem for electricity meters
- Energy metrology software with pulsed outputs to a reference test system including results displaying on a Microsoft® Windows® PC GUI
組み立てられたボードは、テストと性能検証のみの目的で開発されたものであり、販売していません。
設計ファイルと製品
設計ファイル
すぐに使用できるシステム・ファイルをダウンロードすると、設計プロセスを迅速化できます。
設計に使用したコンポーネント、参照指定子、メーカー名や型番などを記入した詳細なリスト
製品
設計や代替製品候補に TI 製品を含めます。
MSPM0G1106 — 64KB フラッシュと 32KB SRAM と 2 個の 12 ビット 4Msps ADC とオペアンプ搭載、80MHz Arm® Cortex®-M0+ マイコン
データシート: PDF | HTML技術資料
種類 | タイトル | 英語版のダウンロード | 日付 | |||
---|---|---|---|---|---|---|
設計ガイド | 単相および分相シャント エネルギー計測のリファレンス デザイン | 英語版 | PDF | HTML | 2024年 9月 10日 |