ZHCSMK4A september 2022 – july 2023 ADS131B26-Q1
PRODUCTION DATA
ADC2y allows measurements of input voltages in three different configurations, as summarized in Table 9-12, Figure 9-9, Figure 9-10, and Figure 9-11.
INPUT CONFIGURATION | POSITIVE MUX CHANNEL | NEGATIVE MUX CHANNEL | GAIN | INPUT RANGE | ABSOLUTE INPUT VOLTAGE | FIGURE |
---|---|---|---|---|---|---|
Single-ended | V0y to V7y | AGNDy | 1, 2, or 4 | Unipolar | 0 V to +FS = VREFy / Gain | Figure 9-9 |
Single-ended | V0y to V7y | AGNDy | 4 | Bipolar | –0.3125 V to 0.3125 V | Figure 9-10 |
Pseudo-differential | V0y to V6y | V7y | 1, 2, or 4 | Bipolar | VV7y ±FS(1) | Figure 9-11 |