ZHCSH75A September 2017 – December 2017 ADS7142
PRODUCTION DATA.
Set the OPMODE_SEL register to 100b or 101b for Manual Mode with AUTO Sequence. The host has to set the SEQ_START bit in START_SEQUENCE register and provide the device address and read bit to start the conversions. To continue with conversions and reading data, the host must provide continuous SCL (Figure 56). In this mode, the SEQ_ABORT bit in ABORT_SEQUENCE register must be set to abort the operation. Then the device operation mode can be changed to another operation mode. In this mode, a register read aborts the AUTO sequence.
In Manual Mode, the device always uses the High Speed Oscillator and the nCLK parameter has no effect. The maximum scan rate is given by Equation 7:
where
Data can be read from the device by providing a device address and read bit followed by continuous SCL as shown in Figure 56.