ZHCSR68 August 2020 DS90LV028A-Q1
PRODUCTION DATA
The DS90LV028A-Q1 differential line receiver is capable of detecting signals as low as 100 mV, over a common-mode range of 0.5 + (VID/2) V to 2.1 - (VID/2) V. This is related to the driver offset voltage which is typically +1.2V. The driven signal is centered around this voltage and may shift ±0.5V around this center point. The ±0.5V shifting may be the result of a ground potential difference between the driver's ground reference and the receiver's ground reference, the common-mode effects of coupled noise, or a combination of the two. The AC parameters of both receiver input pins are optimized for a recommended operating input voltage range of +0.5V to +2.1V (measured from each pin to ground). The device will operate for receiver input voltages up to VCC, but exceeding VCC will turn on the ESD protection circuitry which will clamp the bus voltages.