ZHCSNL2A February 2022 – May 2022 LM74502-Q1 , LM74502H-Q1
PRODUCTION DATA
For the overvoltage setting, refer to the resistor selection procedure described in Overvoltage Protection. Select (R2) = 100 kΩ and R3 = 3.5 kΩ as a standard resistor value to set overvoltage cutoff of 37 V.