ZHCSGC1F June 2017 – March 2021 OPA145 , OPA2145
PRODUCTION DATA
The OPAx145 are specified for operation from 4.5 V to 36 V (±2.25 V to ±18 V); many specifications apply from –40°C to +125°C. Parameters that can exhibit significant variance with regard to operating voltage or temperature are presented in Section 6.7.
Supply voltages larger than 40 V can permanently damage the device; see Section 6.1
Place 0.1-μF bypass capacitors close to the power-supply pins to reduce errors coupling in from noisy or high-impedance power supplies. For more detailed information on bypass capacitor placement, see Section 10.