ZHCSG36D December 2016 – November 2017 TLV8541 , TLV8542 , TLV8544
UNLESS OTHERWISE NOTED, this document contains PRODUCTION DATA.
Because of the ultra-low supply current, changes in common mode voltages cause a noticeable change in the supply current as the input stages transition through the transition region, as shown in Figure 30.
For the lowest supply current operation, keep the input common mode range between V– and 1 V below V+.