ZHCSAV1A April 2013 – September 2019 TMP108
PRODUCTION DATA.
The first byte transmitted by the master is the slave address, with the R/W bit low. The TMP108 then acknowledges reception of a valid address. The next byte transmitted by the master is the pointer register. The TMP108 then acknowledges reception of the pointer register byte. The next byte or bytes are written to the register addressed by the pointer register. The TMP108 acknowledges reception of each data byte. The master can terminate data transfer by generating a start or stop condition.