ZHCSED3B November 2015 – December 2023 TPS3711
PRODUCTION DATA
To make sure the proper logic-high voltage level (VHI), select a pullup resistor value where the pullup voltage divided by the pullup resistor value does not exceed the sink-current capability of the device. Confirm this voltage level by verifying that the pullup voltage minus the open-drain leakage current (ID(leak) ) multiplied by the resistor is greater than the desired VHI. These values are specified in the Section 5.5 .
Use Equation 2 to calculate the value of the pullup resistor.