6.1 Absolute Maximum Ratings
Over operating free-air temperature range (unless otherwise noted).(1)
|
MIN |
MAX |
UNIT |
Supply voltage |
–0.3 |
4 |
V |
Analog I/O voltage(2)(3)(4) |
–0.3 |
VCC + 0.3 |
V |
Control input voltage(2)(4), VIN |
–0.3 |
VCC + 0.3 |
V |
ON-state switch current(5), IIO |
|
±100 |
mA |
Continuous current through VCC or GND |
|
±100 |
mA |
Storage temperature, Tstg |
–65 |
150 |
°C |
(1) Stresses beyond those listed under
Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under
Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to ground, unless otherwise specified.
(3) VI and VO are used to denote specific conditions for VIO.
(4) The input and output voltage rating may be exceeded if the input and output clamp-current ratings are observed.
(5) II and IO are used to denote specific conditions for IIO.