4 Revision History
Changes from G Revision (September 2015) to H Revision
-
Changed the VIN MAX value From: VCC To: 5.5 V in the Recommended Operating Conditions tableGo
Changes from F Revision (June 2015) to G Revision
-
Changed CL TEST CONDITION value for all THD PARAMETERs from 15 pf to 35 pf. Go
Changes from E Revision (May 2013) to F Revision
-
Added Pin Configuration and Functions section, ESD Ratings table, Recommended Operating Conditions table, Feature Description section, Device Functional Modes, Application and Implementation section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable Information sectionGo
-
Split the TS5A22364 and TS5A22362 into separate datasheets and added verbiage to clarify the operation of the shunt resistor. Go
-
Changed the max Ron spec from 1.04 Ω to 1.30 Ω at 2.7 V VCC across full TA. Go
Changes from D Revision (November 2011) to E Revision
-
Added Absolute Maximum Ratings textnoteGo
Changes from C Revision (April 2010) to D Revision
-
Added Medical Imaging to Applications.Go