4 修订历史记录
Changes from A Revision (August 2015) to B Revision
-
Changed Active High. (PWRCTL_POL = 0) To: Active High. (PWRCTL_POL = 1) in Table 48 Go
-
Changed text in the Clock, Reset, and Misc section From: "The PWRCTL_POL is pulled down which results in active low" To: "The PWRCTL_POL is left unconnected which results in active high"Go
-
Deleted R17 from pin 41 of Figure 11 Go
Changes from * Revision (July 2014) to A Revision
-
Added Note ""Power switching must be supported for battery charging applications"" to pin FULLPWRMGMTz / SMBA1/SS_UP in the Pin Functions tableGo
-
Added Note "Individual power control must be enabled for battery charging applications" to pin GANGED / SMBA2 / HS_UP in the Pin Functions tableGo
-
Changed the Handling Ratings table to the ESD Ratings tableGo
-
Changed the Timing Requirements, Power-Up table: Deleted text from the td1 description: "There is no timing relationship between VDD33 and VDD": Added Note 2 to the MIN valueGo
-
Added Note: "An active reset is required.." To the Timing Requirements, Power-Up tableGo
-
Changed text in the Clock, Reset, and Misc section From: "The PWRCTL_POL is pulled down which results in active high power enable" To: "The PWRCTL_POL is pulled down which results in active low power enable"Go