SFFS114 March 2021 DRV8899-Q1
This section provides a Failure Mode Analysis (FMA) for the pins of the DRV8899-Q1. The failure modes covered in this document include the typical pin-by-pin failure scenarios:
Table 4-2 through Table 4-5 also indicate how these pin conditions can affect the device as per the failure effects classification in Table 4-1.
Class | Failure Effects |
---|---|
A | Potential device damage that affects functionality |
B | No device damage, but loss of functionality |
C | No device damage, but performance degradation |
D | No device damage, no impact to functionality or performance |
Figure 4-1 shows the package pin diagram. For a detailed description of the device pins please refer to the 'Pin Configuration and Functions' section in the datasheet.
Following are the assumptions of use and the device configuration assumed for the pin FMA in this section:
Pin Name | Pin No. | Description of Potential Failure Effect(s) | Failure Effect Class |
---|---|---|---|
VM | 1 | Device will not power up | B |
PGND | 2 | Intended Operation | D |
AOUT1 | 3 | Device will signal OCP fault | B |
AOUT2 | 4 | Device will signal OCP fault | B |
BOUT2 | 5 | Device will signal OCP fault | B |
BOUT1 | 6 | Device will signal OCP fault | B |
PGND | 7 | Intended Operation | D |
VM | 8 | Device will signal OCP fault | B |
GND | 9 | Intended Operation | D |
DVDD | 10 | Device external digital power supply stuck low. Device non-operational. | B |
nFAULT | 11 | Device will always be signaling fault | B |
VREF | 12 | Current regulation will be lost | B |
nSCS | 13 | SPI read write functions will be non-functional | B |
VSDO | 14 | SPI read function will be non-functional | B |
SDO | 15 | SPI read function will be non-functional | B |
SDI | 16 | SPI read write functions will be non-functional | B |
SCLK | 17 | SPI read write functions will be non-functional | B |
STEP | 18 | STEP input capability will be lost | B |
DIR | 19 | Direction change capability will be lost | B |
DRVOFF | 20 | Driver control will be lost | B |
nSLEEP | 21 | Device will be in sleep state with OUTx Hi-Z | B |
CPL | 22 | Device charge pump non-operational. Device CPUV fault. | A |
CPH | 23 | Device charge pump non-operational. Device CPUV fault. | A |
VCP | 24 | Device charge pump non-operational. Device CPUV fault. | A |
Pin Name | Pin No. | Description of Potential Failure Effect(s) | Failure Effect Class |
---|---|---|---|
VM | 1 | Device will not power up | B |
PGND | 2 | Device will not power up | B |
AOUT1 | 3 | Device will not be able to drive the load properly | B |
AOUT2 | 4 | Device will not be able to drive the load properly | B |
BOUT2 | 5 | Device will not be able to drive the load properly | B |
BOUT1 | 6 | Device will not be able to drive the load properly | B |
PGND | 7 | Device will not power up | B |
VM | 8 | Device will not power up | B |
GND | 9 | Device will not power up | B |
DVDD | 10 | Device external digital power supply missing. Device non-operational. | B |
nFAULT | 11 | Fault signaling will be lost | B |
VREF | 12 | Current regulation will be lost | B |
nSCS | 13 | SPI read write functions will be non-functional | B |
VSDO | 14 | SPI read function will be non-functional | B |
SDO | 15 | SPI read function will be non-functional | B |
SDI | 16 | SPI read write functions will be non-functional | B |
SCLK | 17 | SPI read write functions will be non-functional | B |
STEP | 18 | Driver control will be lost | B |
DIR | 19 | Driver control will be lost | B |
DRVOFF | 20 | Driver control will be lost | B |
nSLEEP | 21 | Device will be in sleep state | B |
CPL | 22 | Device charge pump non-operational. Device CPUV fault. | B |
CPH | 23 | Device charge pump non-operational. Device CPUV fault. | B |
VCP | 24 | Device charge pump non-operational. Device CPUV fault. | B |
Pin Name | Pin No. | Shorted to Pin No. | Description of Potential Failure Effect(s) | Failure Effect Class |
---|---|---|---|---|
VM | 1 | 2 | Device will not power up | B |
PGND | 2 | 3 | Device will signal OCP fault | B |
AOUT1 | 3 | 4 | Device will signal OCP fault | B |
AOUT2 | 4 | 5 | Device will signal OCP fault | B |
BOUT2 | 5 | 6 | Device will signal OCP fault | B |
BOUT1 | 6 | 7 | Device will signal OCP fault | B |
PGND | 7 | 8 | Device will not power up | B |
VM | 8 | 9 | Device will not power up | B |
GND | 9 | 10 | Device external digital power supply stuck low. Device non-operational. | B |
DVDD | 10 | 11 | Device will reset whenever nFAULT is asserted low | B |
nFAULT | 11 | 12 | Current regulation and fault signalling will be lost | B |
VREF | 12 | 13 | Current regulation and SPI read write functions will be non-functional | B |
nSCS | 13 | 14 | SPI read write functions will be non-functional | B |
VSDO | 14 | 15 | SPI read write functions will be non-functional | B |
SDO | 15 | 16 | SPI read write functions will be non-functional | B |
SDI | 16 | 17 | SPI read write functions will be non-functional | B |
SCLK | 17 | 18 | SPI read write functions and GPIO step input will be non-functional | B |
STEP | 18 | 19 | STEP input and direction change capabilities will be lost | B |
DIR | 19 | 20 | Direction change and OUTx control will be lost | B |
DRVOFF | 20 | 21 | Driver control will be lost | B |
nSLEEP | 21 | 22 | Device charge pump non-operational. Device CPUV fault. | A |
CPL | 22 | 23 | Device charge pump non-operational. Device CPUV fault. | A |
CPH | 23 | 24 | Device charge pump non-operational. Device CPUV fault. | A |
VCP | 24 | 1 | Device charge pump non-operational. Device CPUV fault. | B |
Pin Name | Pin No. | Description of Potential Failure Effect(s) | Failure Effect Class |
---|---|---|---|
VM | 1 | Intended Operation | D |
PGND | 2 | Device will not power up | B |
AOUT1 | 3 | Device will signal OCP fault | B |
'AOUT2 | 4 | Device will signal OCP fault | B |
BOUT2 | 5 | Device will signal OCP fault | B |
BOUT1 | 6 | Device will signal OCP fault | B |
PGND | 7 | Device will not power up | B |
VM | 8 | Intended Operation | D |
GND | 9 | Device will not power up | B |
DVDD | 10 | Low voltage pin max voltage violated. | A |
nFAULT | 11 | Low voltage pin max voltage violated. | A |
VREF | 12 | Low voltage pin max voltage violated. | A |
nSCS | 13 | Low voltage pin max voltage violated. | A |
VSDO | 14 | Low voltage pin max voltage violated. | A |
SDO | 15 | Low voltage pin max voltage violated. | A |
SDI | 16 | Low voltage pin max voltage violated. | A |
SCLK | 17 | Low voltage pin max voltage violated. | A |
STEP | 18 | Low voltage pin max voltage violated. | A |
DIR | 19 | Low voltage pin max voltage violated. | A |
DRVOFF | 20 | Low voltage pin max voltage violated. | A |
nSLEEP | 21 | Driver control will be lost | B |
CPL | 22 | Device charge pump non-operational. Device CPUV fault. | A |
CPH | 23 | Device charge pump non-operational. Device CPUV fault. | A |
VCP | 24 | Device charge pump non-operational. Device CPUV fault. | B |