SLVK162A December   2023  – August 2024 TPS7H6003-SP , TPS7H6013-SP , TPS7H6023-SP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Neutron Displacement Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Facility
    3. 2.3 Test Setup Details
  6. 3Test Results
    1. 3.1 NDD Characterization Summary
    2. 3.2 Data Sheet Electrical Parameters and Associated Tests
  7. 4Applicable and Reference Documents
    1. 4.1 Applicable Documents
    2. 4.2 Reference Documents
  8.   A Appendix: NDD Report Data
  9.   B Revision History

Test Facility

The test facility was the Fast Neutron Irradiation (FNI) Facility of University of Massachusetts Lowell Research Reactor. The neutron fluence for this irradiation was measured using ASTM E-265 Measuring Reaction Rates and Fast Neutron Fluence by Radioactivation of Sulfur-32 and correlated to the measured reactor power level. All irradiation conditions required under ASTM 722 were met. This includes neutron fluence, distribution and uncertainty. The Average Integrated Neutron Fluence, 1-MeV(Si) equivalent, reflects these factors.

Detailed information of the radiation facility is available here.