over operating ambient temperature range (unless otherwise noted)(1)(2) | MIN | MAX | UNIT |
VIN |
Unregulated input(3) |
–0.3 |
45 |
V |
VEN |
Enable input(3) |
–0.3 |
VIN |
V |
VOUT |
Regulated output |
–0.3 |
7 |
V |
TJ |
Junction temperature (grade 1) |
–40 |
150 |
°C |
Junction temperature (grade 0) |
–40 |
165 |
Tstg |
Storage temperature range |
–40 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to GND.
(3) Absolute maximum voltage, withstand 45 V for 200 ms.